Setting up the batteries

SimMan CC is powered by 2 Laerdal Li-ion (Li-ion) batteries. Always use 2 batteries together to power the Simulator and ensure that they are connected properly.

Ensure the Patient Simulator is switched off.

  1. Before starting, follow the Open the torso skin procedure.

  2. Move the stomach foam carefully to one side to avoid pulling on connecting tubes and cables.

  3. Remove the battery cover.

    SM_Batteries_Charge_Insert_01.svg
  4. Disconnect the battery cable from the torso cable as shown.

    SM_Batteries_Charge_Insert_02.svg
  5. Charge the battery.

    SM_Batteries_Charge_Insert_03.svg
  6. Insert the battery and connect it to the torso cable as shown.

  7. Replace the cover once the battery/batteries are connected and in place.

    SM_Batteries_Charge_Insert_04.svg

WARNING

Inserting and connecting the batteries incorrectly, short circuiting or exposure to fluids pose an explosion hazard.

CAUTIONS

  • Ensure the LiveShock cable has been disconnected.

  • Do not use the batteries if they are visibly damaged, malfunctioning or appear to leak electrolyte.

NOTES

  • If both batteries are removed while the simulation is paused, the Patient Simulator will shut down and simulation data will be lost.

  • If battery(ies) are damaged, dispose or recycle in accordance with local regulations, and replace with a new battery.

Refer to Transport and Storage for more infomation relating storing and transporting batteries.